Pack dropped and opened in garage. Water confirmed in pyro fuse cavity. Modules 12, 14 & 15 TBMM PASS (3–4 mV). Module 16 FAIL at 146 mV true imbalance (cells 3.681–3.827 V). Mixed results so far — some connector issues, at least one real cell-group problem.
| VIN | 5YJSA1H25FF091116 |
| Miles / Cycles | 117,988 mi / 1,215 cycles |
| Pack | 1058038-00-F (85 kWh, 16-module) |
| Supercharging | SC01 free (confirmed) |
| Acquisition | Copart Akron non-runner |
| Metric | Value | Notes |
|---|---|---|
| Pack voltage | 361 V | |
| Cell max / min | 3.968–3.970 / 3.622–3.624 V | Static |
| Imbalance | 344–348 mV | No change over 5 days |
| CAC min / max | 208 / 211 Ah | 2.70 Ah spread (~90% of nominal) |
| Temps | 61.7–68.9 °F | Uniform |
Green = flat (<10 mV) • Orange = elevated • Red = high priority
| Mod | Low V | High V | Spread | Flag |
|---|
| Module | SMT Spread | TBMM mV | Result | Interpretation |
|---|---|---|---|---|
| 12 | 81 | 4 | PASS | Connector issue, not cells |
| 14 | 2 | 3–4 | PASS | Healthy — matches low SMT |
| 15 | 1 | 3–4 | PASS | Healthy — matches low SMT |
| 16 | 150 | 146 | FAIL | Real imbalance — detached sense wires |
| 7 | 346 | PENDING | — | Highest priority |
| 6 | 186 | PENDING | — | High priority |
| 9 | 190 | PENDING | — | High priority |
| 10 | 150 | PENDING | — | Medium |
| 11 | 150 | PENDING | — | Medium |
| 1–5,8,13 | 1–3 | PENDING | — | Expected PASS |
Colored boxes = wire color. P = good, F = issue/needs repair, — = not yet checked. Notes in the right column.
| Module | Sensor Wires | BMS Board | Notes |
|---|---|---|---|
| 12 | P P P P P P P | — | Bottom orange riveted (now good). White marks on connector plate bottom. All sensor wires good. |
| 14 | — — — — — — — | — | |
| 15 | P P P P P P P | — | All sensor wires good (top red/yellow/blue/black; bottom orange/green/brown). |
| 16 | — — — — F F — | — | Detached orange and green sense wires (bottom). Real imbalance confirmed. |
| 7 | — — — — — — — | — | Highest priority (SMT 346 mV) |
| 6 | — — — — — — — | — | High priority (SMT 186 mV) |
| 9 | — — — — — — — | — | High priority (SMT 190 mV) |
Use TBMM to balance modules with confirmed imbalance after sense-wire repairs.
| Module | Status | Notes |
|---|---|---|
| 16 | PENDING | Repair sense wires first, then retest and balance if still high |
18 of 22 codes cleared with Toolbox 3. 4 remaining:
Pyro fuse cover gasket failure (cover P/N 1020227-00-C) allowed water into the cavity. This is the source of the f107/w107 and likely contributed to sense-wire issues.
SMT high spread with TBMM low spread = BMB/connector or sense-wire problem, not cell degradation.
Module 12 example: SMT 81 mV → TBMM 4 mV PASS.
For detached sense wires (e.g. Module 16 orange/green):
After repair, balance to the lowest healthy cell group or the pack average, then recheck.
Other sites on 5udyk.com tied to this 85D pack repair and Tesla work.
Lessons for kids (ages 5–15) on battery basics, series/parallel wiring, and how this 85D pack is built. Includes garage activities for the real modules.
ev-school.htmlDIY diagnostic tool project guide. Portable CAN reader for classic Model S/X packs — brick voltages, temps, and imbalance without a laptop.
tpm.5udyk.comNotes for dropping the pack on this 2015 Model S 85D in the driveway using floor jacks instead of a lift.
battery.5udyk.comOut of Spec battery-failure video mapped onto this car’s Scan My Tesla snapshot so failure modes can be checked in order.
teslapack.5udyk.comResearch dossier on this specific 2015 85D (VIN 5YJSA1H25FF091116) — features, Supercharging, recalls, and risks from the Copart listing.
85d.5udyk.comSearch notes for a 2013–2017 Model S with dual motor, rear-facing jump seats, and transferable free Supercharging.
tesla.5udyk.com