2015 Model S 85D Pack Repair

Central data & steps log • Updated October 2026

Quick Stats

4/16
Modules Tested
4
Active Faults
346 mV
Max SMT Spread

Current Status

Pack dropped and opened in garage. Water confirmed in pyro fuse cavity. Modules 12, 14 & 15 TBMM PASS (3–4 mV). Module 16 FAIL at 146 mV true imbalance (cells 3.681–3.827 V). Mixed results so far — some connector issues, at least one real cell-group problem.

Priority next: TBMM Modules 7 (346 mV SMT), 6 (186 mV), and 9 (190 mV). Pyro fuse identified: TPN 1053124-00-A / TSN T15E0022094.
4/16

To-Do List

Vehicle

VIN5YJSA1H25FF091116
Miles / Cycles117,988 mi / 1,215 cycles
Pack1058038-00-F (85 kWh, 16-module)
SuperchargingSC01 free (confirmed)
AcquisitionCopart Akron non-runner

SMT Pack Summary (June 17–23, 2026)

MetricValueNotes
Pack voltage361 V
Cell max / min3.968–3.970 / 3.622–3.624 VStatic
Imbalance344–348 mVNo change over 5 days
CAC min / max208 / 211 Ah2.70 Ah spread (~90% of nominal)
Temps61.7–68.9 °FUniform

Module Voltage Map (SMT Spreads)

Green = flat (<10 mV) • Orange = elevated • Red = high priority

Full Module Table

ModLow VHigh VSpreadFlag

TBMM Progress — 4 of 16

4/16
Module 12: SMT 81 mV → TBMM 4 mV PASS (connector issue). Post-rivet (orange sense wire): 22.51 V • cells 3.749–3.753 V • 4 mV imbalance • 15.0/14.9 °C • thumbs-up. Variance over 6.2 min (158 readings): Hi=268 mV (M1 C3), 2 cells >5 mV. Physical: looks good; all sensor wires good after orange rivet; white marks on connector plate bottom.
Module 14: 22.51 V • 3.749–3.753 V • 3–4 mV • 16.5–16.8 °C • PASS.
Module 15: 22.50 V • cell groups 3.747–3.751 V • imbalance 3–4 mV • temps 13.5–13.7 °C • variance max 1 mV • PASS. All sensor wires good (top: red/yellow/blue/black; bottom: orange/green/brown).
Module 16: 22.51–22.52 V • cells 3.681–3.827 V (5:3.681 / 6:3.827) • imbalance 146 mV FAIL • temps 11.7–12.5 °C. Variance stable. Real cell-group imbalance confirmed. Sensor leads: detached orange and green wires on bottom.

SMT vs TBMM Comparison

ModuleSMT SpreadTBMM mVResultInterpretation
12814PASSConnector issue, not cells
1423–4PASSHealthy — matches low SMT
1513–4PASSHealthy — matches low SMT
16150146FAILReal imbalance — detached sense wires
7346PENDING—Highest priority
6186PENDING—High priority
9190PENDING—High priority
10150PENDING—Medium
11150PENDING—Medium
1–5,8,131–3PENDING—Expected PASS

Physical Inspection (Sensor Leads & BMS Board)

Colored boxes = wire color. P = good, F = issue/needs repair, — = not yet checked. Notes in the right column.

Module Sensor Wires BMS Board Notes
12 P P P P P P P — Bottom orange riveted (now good). White marks on connector plate bottom. All sensor wires good.
14 — — — — — — — —
15 P P P P P P P — All sensor wires good (top red/yellow/blue/black; bottom orange/green/brown).
16 — — — — F F — — Detached orange and green sense wires (bottom). Real imbalance confirmed.
7 — — — — — — — — Highest priority (SMT 346 mV)
6 — — — — — — — — High priority (SMT 186 mV)
9 — — — — — — — — High priority (SMT 190 mV)

Balancing

Use TBMM to balance modules with confirmed imbalance after sense-wire repairs.

ModuleStatusNotes
16PENDINGRepair sense wires first, then retest and balance if still high

Pass Criteria

Fault Summary

18 of 22 codes cleared with Toolbox 3. 4 remaining:

Root Cause

Pyro fuse cover gasket failure (cover P/N 1020227-00-C) allowed water into the cavity. This is the source of the f107/w107 and likely contributed to sense-wire issues.

Connector Issue vs Real Cell Imbalance

SMT high spread with TBMM low spread = BMB/connector or sense-wire problem, not cell degradation.

Module 12 example: SMT 81 mV → TBMM 4 mV PASS.

Sense Wire Repair Guide (Riveting Method)

For detached sense wires (e.g. Module 16 orange/green):

  1. Clean the tab and wire end.
  2. Use a small rivet or crimp to reattach.
  3. Confirm continuity and retest with TBMM.

How to choose the balance point

After repair, balance to the lowest healthy cell group or the pack average, then recheck.

Repair Timeline

May 2026 — Purchased Copart Akron non-runner. 22 fault codes.
May — Replaced 12V AGM + charge port door (Heli-Coil).
June 17–23 — SMT readings: 344–348 mV imbalance, healthy CAC 208–211 Ah, static.
June 20 — Toolbox 3: cleared 18/22 codes, firmware 2025.20.6, brief L1 charge (+7 mi). f107 re-latched.
July — Ervine’s diagnostic.
Oct — Pack dropped (Vevor jack method), opened. Water in pyro fuse cavity confirmed. Module 12 TBMM: 4 mV PASS (in-pack). Module 14 TBMM: 3–4 mV PASS. Module 15 TBMM: 3–4 mV PASS (22.50 V, cells 3.747–3.751 V, 13.5–13.7 °C). Module 16 TBMM: 146 mV FAIL (22.51–22.52 V, cells 3.681–3.827 V). Pyro fuse TPN 1053124-00-A logged. Module 16 retested after removal — same 146 mV. Detached orange and green sense wires found on bottom of Module 16. Module 12 physical inspection: looks good overall, sensor wires good except bottom orange needs rivet; white marks on connector plate bottom. Module 12 out-of-pack TBMM retest: 22.51 V, cells 3.749–3.753 V, 4 mV, 13.7–13.8 °C (PASS); variance Hi=23 mV over ~2 min. Module 15 physical: all sensor wires good (top red/yellow/blue/black; bottom orange/green/brown). Module 12 bottom orange sense wire riveted; post-repair TBMM: 22.51 V, cells 3.749–3.753 V, 4 mV PASS, 15.0/14.9 °C, thumbs-up (variance Hi=268 mV over 6.2 min / 158 readings).
Next — TBMM priority modules 7, 6, 9. Repair Module 16 sense wires then retest/balance. Inspect sensor leads and BMS boards on other tested modules. Address pyro fuse/cover.