2015 Model S 85D Pack Repair

VIN 5YJSA1H25FF091116 • Central data & steps log
Updated October 2026 • TBMM progress 3/16

Quick Stats

3/16
Modules Tested
4
Active Faults
346 mV
Max SMT Spread

Current Status

Pack dropped and opened in garage. Water confirmed in pyro fuse cavity. Modules 12 & 14 TBMM PASS (3–4 mV). Module 16 FAIL at 146 mV true imbalance (cells 3.681–3.827 V). Mixed results so far — some connector issues, at least one real cell-group problem.

Priority next: TBMM Modules 7 (346 mV SMT), 6 (186 mV), and 9 (190 mV). Pyro fuse identified: TPN 1053124-00-A / TSN T15E0022094.
3/16

Vehicle

VIN5YJSA1H25FF091116
Miles / Cycles117,988 mi / 1,215 cycles
Pack1058038-00-F (85 kWh, 16-module)
SuperchargingSC01 free (confirmed)
AcquisitionCopart Akron non-runner

SMT Pack Summary (June 17–23, 2026)

MetricValueNotes
Pack voltage361 V
Cell max / min3.968–3.970 / 3.622–3.624 VStatic
Imbalance344–348 mVNo change over 5 days
CAC min / max208 / 211 Ah2.70 Ah spread (~90% of nominal)
Temps61.7–68.9 °FUniform

Module Voltage Map (SMT Spreads)

Green = flat (<10 mV) • Orange = elevated • Red = high priority

Full Module Table

ModLow VHigh VSpreadFlag

TBMM Progress — 3 of 16

3/16
Module 12: SMT 81 mV → TBMM 4 mV PASS (connector issue).
Module 14: 22.51 V • 3.749–3.753 V • 3–4 mV • 16.5–16.8 °C • PASS.
Module 16: 22.51–22.52 V • cells 3.681–3.827 V (5:3.681 / 6:3.827) • imbalance 146 mV FAIL • temps 11.7 °C. Variance stable (max 1 mV). Real cell-group imbalance confirmed.

SMT vs TBMM Comparison

ModuleSMT SpreadTBMM mVResultInterpretation
12814PASSConnector issue, not cells
1423–4PASSHealthy — matches low SMT
16150146FAILReal imbalance confirmed
7346PENDING—Highest priority
6186PENDING—High priority
9190PENDING—High priority
10150PENDING—Medium
11150PENDING—Medium
1–5,8,13,151–3PENDING—Expected PASS

Physical Inspection (Sensor Leads & BMS Board)

Confirmation of visual/physical inspection for sensor leads and the BMS circuit board on each module. Update as modules are opened or inspected.

Module Sensor Leads Inspected Sensor Leads Issues BMS Board Inspected BMS Board Issues
12PENDING—PENDING—
14PENDING—PENDING—
16PENDING—PENDING—
7PENDING—PENDING—
6PENDING—PENDING—
9PENDING—PENDING—
10PENDING—PENDING—
11PENDING—PENDING—
1–5, 8, 13, 15PENDING—PENDING—

Balancing (TBMM)

The TBMM (Electric Avenue) supports automatic active balancing of modules outside the pack. Good candidate for Module 16 (confirmed 146 mV real imbalance).

How to balance with TBMM (from electric-avenue.us/tbmm and demo):
  • Connect TBMM to the module’s BMB connector with the included cable.
  • Power via USB-C (wall adapter, power bank, or phone).
  • Diagnose voltages first and confirm board health.
  • Use the Wi-Fi web interface to set the balance point (target voltage) and turn balancing on/off — easiest method.
  • Let it run; demo showed reduction from ~10–18 mV to ~2 mV over hours to ~24 h.
  • Monitor progress on the display or web interface. Retest imbalance after.

How to choose the balance point

The balance point is the target voltage the TBMM balances the cell groups toward.

For Module 16 (current range ~3.681 V low to 3.827 V high):

General approach:

After balancing, recheck the imbalance. Goal is ≤ 6 mV to match the pass criteria.

Log balancing sessions and post-balance results here as they are done.

Module Balanced? Balance Point Pre mV Post mV Notes
16PENDING—146—Real imbalance confirmed; good candidate
12——4—Already PASS — no need
14——3–4—Already PASS — no need

Pass Criteria

Cell group imbalance ≤ 6 mV = PASS. High ≤ 4.20 V, low ≥ 3.00 V.

Fault Summary

Peak at acquisition: 22 codes. After Toolbox (June 20): cleared to 4 remaining.

CodeStatusNotes
BMS_f107Re-latchesHard block on drive/charge — cell voltage sensor inaccurate
BMS_w107PersistsWarning version of f107
BMS_u018PersistsSOC imbalance limiting
BMS_a129PersistsBMB VSH connector — water entry confirmed
BMS_u008, othersCleared18 codes cleared via Toolbox + 12V / door / CAN redeploy

Root Cause

Primary: Pyro fuse cover (1020227-00-C) gasket failure → water entry. Confirmed water + corrosion in cavity.

Pyro fuse identified: ASY,FUSE,HVBAT,HI DURA,83 • TPN 1053124-00-A • TSN T15E0022094.

Contributing: deep discharge, 12V failure, charge port door swap without relearn, BMB connector corrosion.

What “Connector Issue” Means

On Module 12 the site notes a connector issue because the large voltage spread reported by Scan My Tesla disappeared when the module was measured directly with the TBMM.

The cells themselves were healthy. The BMS was simply reading them incorrectly through the connector / sense-lead path. This is a false or inflated reading, not real cell imbalance.

Why This Happens

The BMS reads cell-group voltages through sense leads and BMB (Battery Management Board) connectors. Anything that adds resistance or corrosion in that path can make the BMS report a fake spread even when the cells are fine.

Common causes on these packs:

Module 14 showed the same pattern (low true imbalance on TBMM). Module 16 is the opposite: its 146 mV TBMM result confirmed a real cell-group imbalance.

SMT vs TBMM

Healthy modules typically show ≤ 6 mV imbalance on TBMM. Anything significantly higher is treated as a real issue until proven otherwise.

Next Diagnostic Steps

For modules that show a connector-style pattern (high SMT, low TBMM):

The Physical Inspection table in the TBMM tab is ready to log those results as modules are opened.

Repair Timeline

May 2026 — Purchased Copart Akron non-runner. 22 fault codes.
May — Replaced 12V AGM + charge port door (Heli-Coil).
June 17–23 — SMT readings: 344–348 mV imbalance, healthy CAC 208–211 Ah, static.
June 20 — Toolbox 3: cleared 18/22 codes, firmware 2025.20.6, brief L1 charge (+7 mi). f107 re-latched.
July — Ervine’s diagnostic. GLEV remote: water / possible new pack.
Sept — Picked up; decided DIY pack drop.
Oct — Pack dropped (Vevor jack method), opened. Water in pyro fuse cavity confirmed. Module 12 TBMM: 4 mV PASS. Module 14 TBMM: 3–4 mV PASS. Module 16 TBMM: 146 mV FAIL (22.51–22.52 V, cells 3.681–3.827 V, 11.7 °C). Pyro fuse TPN 1053124-00-A logged.
Next — TBMM priority modules 7, 6, 9. Address Module 16 imbalance (consider TBMM balancing) and pyro fuse/cover. Inspect sensor leads and BMS boards on tested modules.